5.4 MODULE 4 - S ETPOINT O UTPUT P ARAMETERS ( ????? )
4-SPt
PAR
PARAMETER MENU
Pro
SP-ASN
Setpoint
SP-ACt
Setpoint
SP-ON
Setpoint On
SP-OFF
Setpoint Off
O-tOUt
Setpoint
StOP-t
Stop Timer
AUtO-r
Timer/Counter
OrSt-r
Setpoint
O P-UP
Setpoint
Assignment
Output Action
Output
Auto Reset
Output Reset
Output
Time-out
with Display
Reset
Power-up
State
Module 4 is the programming module for the Setpoint Output parameters.
Some parameters will not appear depending on the Setpoint Assignment and
Setpoint Output Action selected.
SETPOINT ASSIGNMENT
SETPOINT OUTPUT TIME-OUT
?????? ? ????????? to ? ?????????
? ????????
This parameter is only active if the Setpoint Action is set to Timed Output mode
?????? ?
? ?????
?????
?????
( ????? ). Enter the time duration the Setpoint Output will remain ON once it is
activated. This value is always entered in minutes, seconds, and hundredths of
seconds format. The maximum value is 99 minutes 59.99 seconds.
Select the display for Setpoint assignment.
STOP TIMER
?????? ?
?
?
??????
?
SETPOINT OUTPUT ACTION
?????
?????
????? ??????
This parameter selects the action of the Setpoint output as shown below.
??
????
?? ?????
Stops the Timer when the Setpoint output activates ( ???? ) or deactivates
( ????? ). Select ?? if the output should not affect the Timer Run/Stop status.
The Timer Stop condition is cleared when a Timer Reset occurs, or a Time
Start edge is applied on the Timer input.
SPT ACTION DESCRIPTION
OUTPUT ACTIVATES
OUTPUT DEACTIVATES
?????
Latched Output Mode
When Time or Count
= Setpoint On value
At Manual Reset
(if ?????? = ??? )
?
?????
??????
Timed Output Mode
On-Off Output Mode
When Time or Count After Setpoint
= Setpoint On value Output Time-Out
When Time or Count When Time or Count
?? Setpoint On value ?? Setpoint Off value
??????
?
TIMER/COUNTER AUTO RESET
??
????
?? ?????
Automatically resets the Setpoint Assigned display value when the Setpoint
SETPOINT ON
Output activates ( ???? ) or deactivates ( ????? ). Select ?? if the output should
????? ?
? ?????
?????
??????
??????
not cause a display reset.
This parameter determines when the Setpoint output will activate. The output
SETPOINT OUTPUT RESET WITH DISPLAY RESET
can activate at a programmed Setpoint Value or can be set to activate when the
Timer starts ( ?????? ) or stops ( ?????? ).
Selecting ????? displays a sub-menu where the Setpoint Value is entered. If
the Setpoint is assigned to the Timer, the value is entered in the same display
?????? ?
? ???
???
??
format as the selected Timer Range.
Select ??? to have the Setpoint Output deactivate (reset) when the Setpoint
?? ? ??? ?
? ??????
?????? to ??????
Assigned display resets. Reset can occur by the RST ? key or the User Input,
if programmed for that function. Select ?? if the Setpoint output should not
reset when the display resets.
?????? ?
?
?????
?
???
SETPOINT OFF
?????
??????
??????
The Setpoint Off parameter only appears if the Setpoint Action is set to
On-Off Output mode ( ?????? ). In this mode, the Setpoint OFF parameter
determines when the Setpoint Output will deactivate. The output can be
programmed to deactivate at a Setpoint Off Value or can be set to deactivate
when the Timer starts ( ?????? ) or stops ( ?????? ).
Selecting ????? displays a sub-menu where the Setpoint Off Value is
entered. If the Setpoint is assigned to the Timer, the value is entered in the same
display format as the selected Timer Range.
SETPOINT OUTPUT POWER-UP STATE
?? ???? ? ???
??
????
???? will restore the output to the same state it was at before the meter was
powered down. ?? will activate the output at power up. ??? will deactivate the
output at power up. This parameter is not active when the Setpoint Action is
selected for timed output mode.
?? ? ??? ?
? ??????
?????? to ??????
10
相关PDF资料
LFSTBEB7361 BOARD DEV ACCELEROMETER MMA7361L
LFSTBEB7455 BOARD DEV ACCELEROMETER MMA7455L
LFSTBEB8450 BOARD DEV ACCELEROMETER MMA8450
LFSTBEB845X EVAL BOARD FOR MMA845XQ
LH1518AT RELAY SSR SPST 250V 300MA 6DIP
LI12-1A79 RELAY REED SPST 1A 12V
LK1AF-24V RELAY GEN PURPOSE SPST 5A 24V
LKG1AF-24V-16-1 RELAY GEN PURPOSE SPST 16A 24V
相关代理商/技术参数
LD50 制造商:General Tools 功能描述:Deluxe Lightning Detector 制造商:General Tools 功能描述:DETECTOR LIGHTNING
LD-50 制造商:API TECHNOLOGIES 功能描述: 制造商:API Technologies Corp 功能描述:
LD5000 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE
LD5001 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE
LD5002 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE
LD5003 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE
LD5004 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE
LD5005 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE